Automated electric generators test bench for low power wind energy applications
DOI:
https://doi.org/10.37537/rev.elektron.4.1.88.2020Keywords:
Testing, Automation, Wind Turbine, Generator, ControlAbstract
This paper presents the development of an automated electric generators test bench for low power wind energy in urban applications. The bench allows testing electric generator under similar operating conditions to real, electric generator coupled to a wind turbine in urban environments, which allows to determine specific parameters: electric current, voltage, power.Downloads
References
Cammesa. (2019). Compania Administradora del Mercado Mayorista Eléctrico S.A. Retrieved from https://despachorenovables.cammesa.com/renovables/
Ahmed, E., & Ahmed, S. (2018). Vertical Axis Wind Turbine. 10.13140/RG.2.2.12592.81927.
Agotegaray, J. C., Pinzon Montes, A. L., & Iratchet Prado, M. S. (2017). “Prototipo de aerogenerador de eje vertical Giromill”. CLADI 2017. Congreso Latinoamericano de Ingenieria.
Gourieres, D. L. (1983). Energía Eólica. Teoría, concepción y cálculo práctico de las instalaciones. Masson S.A.
Piggot, Hugh (2003). How to build a wind generator - the axial flux alternator. Link: https://www.scoraigwind.com/pirate/Hugh Piggott Axial-flow PMG wind turbine May 2003.pdf
Siemens. (2012, Febrero). SIMOTICS Low-voltage Motors. E86060- K5581-A111-A4-7600.
AG, S. (2013, Febrero ). "Convetidor SINAMICS V20". A5E31842763.
AG, S. (2008, Agosto). "Manual del sistema de automatizacion S7-200". 6ES7298--8FA24--8DH0.
Latoufis, K.C., Messinis, G.M., Kotsampopoulos P.C & Hatziargyriou N.D. (2012). Axial flux permanent magnet generator design for low cost manufacturing of small wind turbinesGenerador axial. Wind Engineering Volume 36, no. 4, 2012 pp 411-442.
Downloads